![]() Outdoor air intake openings must meet the provisions of Sections 401.4 and 401.5 and must include a motorized damper that is activated by the whole house ventilation system controller. Intermittent dryer exhaust, intermittent range hood exhaust, and intermittent toilet room exhaust airflow rates above the residential dwelling or sleeping unit minimum ventilation rate are exempt from the balanced airflow calculation.Īir handler fans shall be permitted that have multi-speed or variable speed supply airflow control capability with a low speed operation not greater than 25 percent of the rated supply air flow capacity during ventilation only operation. The system shall be design and balanced to meet the pressure equalization requirements of Section 501.4. For R-2 dwelling and sleeping units, the system is required to have balanced whole house ventilation but is not required to have distributed whole house ventilation where the not distributed system coefficient from Table 403.4.3 is utilized to correct the whole house mechanical ventilation rate. The supply fan shall meet the requirements of Section 403.4.6.2. ![]() The exhaust fan shall meet the requirements of Section 403.4.6.1. The flow rate test results shall be submitted and posted in accordance with Section 403.4.6.7. The tested and balanced total mechanical exhaust airflow rate is within 10 percent or 5 cfm, whichever is greater, of the total mechanical supply airflow rate. The supply and exhaust fans shall have airflow that is within 10 percent of each other. ![]() A balanced whole house ventilation system shall include both supply and exhaust fans. The ventilation system, including transfer fan-powered terminal units shall be designed to supply the required rate of ventilation air continuously during the period the building is occupied, except as otherwise stated in other provisions of the code.Ĥ03.4.6.3 Balanced whole house ventilation system. Ventilation rates for occupancies not represented in Table 403.3.1.1 shall be those for a listed occupancy classification that is most similar in terms of occupant density, activities and building construction or shall be determined by an approved engineering analysis. The occupant load utilized for design of the ventilation system shall not be less than the number determined from the estimated maximum occupant load rate indicated in Table 403.3.1.1. ![]() Outdoor air shall be supplied directly to each occupiable space from an air handling unit through a fully ducted path or ducted to within 12 inches of the return air opening of a fan-powered terminal unit used to transfer the outdoor air to the occupiable space. In each occupiable space, the ventilation system shall be designed to deliver the required rate of outdoor airflow to the breathing zone. Ventilation systems shall be designed to have the capacity to supply the minimum outdoor airflow rate determined in accordance with this section. An experienced Lennox® Dealer will be able to recommend a home comfort system that can not only improve your family’s comfort, but also help lower your utility bills.403.3.1.1 Outdoor airflow rate. Determining the appropriate capacityĪ qualified HVAC dealer will calculate your home’s CFM and take into account various factors such as the number of windows you have, what type of climate you live in, and even your family’s temperature preferences to determine the appropriate system capacity. Too much or too little airflow can negatively impact your system performance and even cause damage to its components. Having an accurate estimate of your home’s CFM is key to choosing an HVAC system with the right capacity for your space and needs. Larger homes circulate more air (since there’s more space for it to move around), so they will have a higher CFM. Cubic Feet Per Minute (CFM) is a measurement of airflow volume, determined by how many cubic feet of air pass by a stationary point in one minute.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |